2E OD2000 UPS, 2000VA/1800W, LCD, USB, 3xSchuko 2E-OD2000

SKU: 2E-OD2000

The war in Ukraine is not abating, the enemy continues to destroy critical infrastructure, in particular the facilities of the country’s energy system. In order to restore the damaged and ensure the stability of the power system, power engineers resort to fan and sometimes emergency shutdowns. Ukrainians understand the proposed measures and are trying to adapt to new realities: they are looking for solutions to provide electricity not only to their own homes, but also to critical public institutions such as hospitals, medical centers, and to meet business needs.

Characteristics
Where to buy
Type Online with double conversion
Installation type Tower
Maximum output power, VA 2000
Effective output power, W 1800
Input voltage range, V 110-176 (linear derating between 50% and 100% load), 176-280 (no derating), 280-300 (50% derating)
Input frequency, Hz 40-70 (automatic detection)
Maximum current, A 1
THD input ≤6%
Output voltage range, V 208/220/230/240
Output frequency, Hz 45-55 or 55-65 (synchronized range); 50-60±0.1 (battery mode)
THD output ≤2% linear load; ≤5% non-linear load
Inverter overload 105%-125% for 1 min
125%-150% for 30 s
>150% for 300 ms
Efficiency ≥ 91% (Mains mode), ≥ 86% (Battery mode), ≥ 96% (ECO mode)
Sockets 3xSchuko
Built-in battery 12V/ 9Ah x4
Ability to connect external batteries 12V/ 9Ah x4
Interfaces RS-232, USB, optional SNMP adapter
Display Yes
Typical recharge time (up to 90%), h 3
Noise level, dB ≤50
Operating temperature 0-40 °C
Relative humidity 0-95% (non-condensing)
Colour Black
Protection class IP 20
Protection Overheat protection, fan test protection, overload protection, output short circuit protection, low battery protection
Dimensions (WxDxH), mm 191х418х335
Weight, kg 18
Manufactured China
Warranty 2 years for electronics, 1 year for batteries
Manual
High resolution photo
Drivers&Software

Considering the military present, 2E brand uninterruptible power supply is a must-have for almost everyone. The model has a power of 2,000 VA/1,800 W. 2E OD2000 type: online double conversion. The main advantage of devices of this type is the ability not only to prevent interruptions in the power supply of important «consumers», but also to significantly improve the quality of the supplied current. Input 110 ~ 300 V AC, the UPS converts and outputs the required ideal 208/220/230/240 V (voltage adjustable). The lack of switching between modes (mains to battery) allows to minimize the risk of damage to «sensitive» equipment. In particular, such UPSs are used for uninterrupted power supply of medical equipment, for data centers and enterprises with a continuous production cycle.

 

The operating frequency range of 2E OD2000 model is within 40 ~ 70 Hz (automatic detection). If the inverter of the device fails or the input current is too high, the bypass mode is automatically activated: the bypass voltage range is -25% ~ +15%. The UPS is equipped with four batteries (12 W/9 Ah), which restore the charge to 90% in just 3 hours! The charging current (max.) is 1 A. In addition, two Schuko sockets, RS-232 connectors, USB and an optional SNMP adapter are provided. An LCD display built into the front panel displays the device’s operating status, including error codes.

 

With a weight of 18 kg, the device has dimensions of 191 × 418 × 335 mm. Installation type: TOWER. The noise level is 50 dB. The product has IP20 protection degree, as well as protection against short circuit, overload, overheating, full battery discharge and the fan check ability. In case of emergency, users can use the EPO port, which is built into the rear panel, for emergency shutdown of the UPS.